IEC 62629-12-1-2014 3D顯示器--第12-1部分:戴眼鏡式立體顯示測量方法--光學 3D Display devices – Part 12-1: Measuring methods for stereoscopic displays using glasses – Optical
- 標準類別:
- 標準大?。?/li>
- 標準編號:IEC 62629-12-1-2014
- 標準狀態(tài):現行
- 更新時間:2023-09-27
- 下載次數:次
This part of IEC 62629 determines the following measuring methods for characterizing the performance of stereoscopic display devices using either active or passive glasses.
This standard focuses on the types of stereoscopic displays using glasses as follows:
The types of stereoscopic displays reproducing temporally interlaced images and applicable glasses are:
– displays representing temporally interlaced (high frame rate) images and active glasses (time dividing shutter glasses), and
– displays with front screen switchable polarizer representing temporally interlaced images and linear or circular polarizer passive glasses.
The types of stereoscopic displays reproducing spatially interlaced images and applicable glasses are: – displays with patterned retarder representing spatially interlaced images and linear or circular polarizer passive glasses. Some parts of these measuring methods may also be applied to other types of stereoscopic displays using glasses not listed above.
The measuring items for the sets of stereoscopic display and glasses are as follows:
a) luminance,
b) luminance uniformity,
c) interocular luminous difference,
d) dark-room contrast ratio,
e) interocular contrast difference,
f) colour gamut,
g) white chromaticity,
h) white chromatic uniformity,
i) interocular chromatic difference,
j) interocular crosstalk, and
k) interocular crosstalk screen position dependency (interocular crosstalk uniformity).
The measuring parameters are as follows:
l) viewing direction dependency,
m) dependency on in-plane rotation of lens, n) dependency on tilt angle of lens, and
o) viewing distance dependency.
The measuring items for the glasses are as follows:
p) transmittance (open state),
q) extinction ratio,
r) colour shift (open state, on-state),
s) interocular transmittance,
t) interocular contrast difference,
u) interocular chromatic difference,
v) response time (open state to/from closed state) of active glasses, and
w) uniformity of lens. The measuring parameters are as follows:
x) angular characteristic, and
y) temperature dependency.dition 1.0 2014-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
3D Display devices –
Part 12-1: Measuring methods for stereoscopic displays using glasses – Optical
Dispositifs d'affichage 3D –
Partie 12-1: Méthodes de mesure pour les écrans stéréoscopiques utilisant des
lunettes – Optique
IEC 62629-12-1:2014
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright ? 2008 IEC, Geneva, Switzerland
All rights reserved. Unless otherwise
-
GB/T 1094.1-2013電力變壓器 第1部分:總則 2023-09-27
-
GB/T 706-2016熱軋型鋼 2023-09-27
-
JB/T 10216-2013電控配電用電纜橋架 2023-09-27
-
GB 9706.1-2020醫(yī)用電氣設備 第1部分:基本安全和基本性能的通用要求 2023-09-27
-
GB/T 10801.2-2018絕熱用擠塑聚苯乙烯泡沫塑料(XPS) 2023-09-27
-
GB 51251-2017建筑防煙排煙系統(tǒng)技術標準 2023-09-27
