我与乡下少妇的性事_色琪琪综合男人的天堂aⅴ视频_大胸喂奶秘书3p高h_国产一区二区视频在线播放_国产老头gay和老头gay视频_中文字幕亚洲欧美_国产男人搡女人免费视频_伊人色综合久久天天五月婷_崔雪莉被金秀贤握胸动态图_毛片在线视频观看

首頁 > 標(biāo)準(zhǔn)下載>ASTM D5185-2018 用感應(yīng)耦合等離子體原子發(fā)射光譜法測定用過和用過潤滑油及基礎(chǔ)油中多種元素的試驗(yàn)方法 Standard Test Method for Multielement Determination of Used and Unused Lubricating Oils and Base Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)免費(fèi)下載
ASTM D5185-2018 用感應(yīng)耦合等離子體原子發(fā)射光譜法測定用過和用過潤滑油及基礎(chǔ)油中多種元素的試驗(yàn)方法 Standard Test Method for Multielement Determination of Used and Unused Lubricating Oils and Base Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) ASTM D5185-2018 用感應(yīng)耦合等離子體原子發(fā)射光譜法測定用過和用過潤滑油及基礎(chǔ)油中多種元素的試驗(yàn)方法 Standard Test Method for Multielement Determination of Used and Unused Lubricating Oils and Base Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)

ASTM D5185-2018 用感應(yīng)耦合等離子體原子發(fā)射光譜法測定用過和用過潤滑油及基礎(chǔ)油中多種元素的試驗(yàn)方法 Standard Test Method for Multielement Determination of Used and Unused Lubricating Oils and Base Oils by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)

  • 標(biāo)準(zhǔn)類別:
  • 標(biāo)準(zhǔn)大小:
  • 標(biāo)準(zhǔn)編號(hào):ASTM D5185-2018
  • 標(biāo)準(zhǔn)狀態(tài):現(xiàn)行
  • 更新時(shí)間:2023-07-19
  • 下載次數(shù):
標(biāo)準(zhǔn)簡介

1.1 This test method covers the determination of additive elements, wear metals, and contaminants in used and unused lubricating oils and base oils by inductively coupled plasma atomic emission spectrometry (ICP-AES). The specific elements are listed in Table 1. (A) These wavelengths are only suggested and do not represent all possible choices. 1.2 This test method covers the determination of selected elements, listed in Table 1, in re-refined and virgin base oils. 1.3 For analysis of any element using wavelengths below 190 nm, a vacuum or inert-gas optical path is required. The determination of sodium and potassium is not possible on some instruments having a limited spectral range. 1.4 This test method uses oil-soluble metals for calibration and does not purport to quantitatively determine insoluble particulates. Analytical results are particle size dependent, and low results are obtained for particles larger than a few micrometers.2 1.5 Elements present at concentrations above the upper limit of the calibration curves can be determined with additional, appropriate dilutions and with no degradation of precision. 1.6 For elements other than calcium, sulfur, and zinc, the low limits listed in Table 2 and Table 3 were estimated to be ten times the repeatability standard deviation. For calcium, sulfur, and zinc, the low limits represent the lowest concentrations tested in the interlaboratory study. (A) where: X = mean concentration, μg/g. (A) where: X = mean concentration, μg/g. 1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determ

標(biāo)準(zhǔn)截圖
下一條:返回列表
版權(quán):如無特殊注明,文章轉(zhuǎn)載自網(wǎng)絡(luò),侵權(quán)請聯(lián)系cnmhg168#163.com刪除!文件均為網(wǎng)友上傳,僅供研究和學(xué)習(xí)使用,務(wù)必24小時(shí)內(nèi)刪除。